Unit Specifications:
(Ambient Temp. 68’F)
Energy Factor: |
2.11  |
Dimensions: |
18" x 14" x 13"(height) |
Output: |
7000 BTUs |
Ist
Hour Rating: |
43 Gallons  |
Max. Water Temperature: |
135° F (10° F between open and close) |
Weight: |
48 lbs |
Noise Level: |
about 50 db |
Electrical Specifications:
Volts: |
110 |
Amps: | 12 startup/6 operating |
Phase: |
1 |
Frequency: |
60 Hz |
Note: All measurements have been acquired using DOE testing standards.
Additional Requirements:
- AirTap™ needs at least 5" clearance
on the top.
- AirTap™ should be installed indoors.
- Water heater must be installed near a
drain available to expel condensate captured during air
energy processing. During periods of high humidity, the
level of condensate can be up to 1 quart per day.
- The AirTap™ will operate under extremely
cold conditions, but it is not recommended to install the
unit in a location where the ambient temperature is below
35° F mostly, as the efficiency of the unit in such
conditions will drop by approximately 50%.
|
|
|